Fire certification

BACK Mass Transit Marine Aerospace/Defence Building/Construction Fire Resistance Test

Certification for Mass Transit

Performance in Reaction to Fire Test

Test Performance of Borden Cellobond phenolic FRP laminate Performance Category
BS476: Part 7
BS476: Part 6
BS6853 B5.2

NF F 16-101
ASTM E162
ASTM E662
DIN 5510
ASTM E84
BS6853
(EN 2825, 2826)
class 1
i = 0.8, I=8.1
Ao(ON) = < 1.0
Ao(OFF)= < 1.5
M1/F1
Flame spread index = 2
Non-flaming 7; Flaming 23
Flammability S4; Smoke SR2; Drips ST2
Flame spread 5, Smoke Density 5
R=0.27
Class 1
Class 1/0
Meets London Underground requirements

M1/F1
Very low flame spread
Very low Smoke
Best possible rating
Class 1 (best possible)
Category 1A

TOP

Certification for Marine

Performance in Fire Resistance Tests

Test Test Type Performance Achieved
BS476: Part 22
ISO 9705
IMO MSC.36(63)
IMO MSC.61(67)
NES 711
NFX 10-702
NES 713
Fire insulation and Integrity
Room Corner Test
IMO Code Of Safety For High Speed Craft
Smoke &Toxity
Smoke Index
Smoke Density
Toxicity Index
Greater than 1 hour insulation and integrity
Fire Restricting Material
Conformance to Resolution
Performance in these test is usually laminate and design dependent

TOP

Certification for Aerospace/Defence

Performance in Fire Resistance Tests

Test Performance of Borden Cellobond FRP Phenolic laminate and ETP Performance Category
CAA 8 Issue 2
ATS 1000.001
BS2782
BS476 Part 6
BS476 Part 7
MIL-R-9299C Type A
MIL-R-9299C Type B
FAR/JAR 25.853(c&d)
FAR/JAR 25.853(c&d)
FAR/JAR 25.853(c&d)

DS 1.5 mins, 5, 4 mins, 25
>250 ºC
Class 0
Class 1


APP.F. Pt.IV(g) Heat release
APP.F.Pt.V (b) smoke emission test
APP.F Pt.I (a) (1) (i) flammability test
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass

TOP

Certification for Building/Construction

Performance in Reaction to Fire Test

Test Performance of Borden Cellobond phenolic FRP laminate Performance Category
BS476: Part 7
BS476: Part 6
BS6853 B5.2
DIN 4102
NEN1076
(is replaced by NEN 6065)
class 1
i = 0.8, I=8.1
Ao(ON) = <1.0 , Ao(OFF) = <1.5
class B1
class 1
Class 1
Class 1/0
Meets London Underground requirements
Class B1
Class 1

TOP

Fire Resistance Tests

Performance in Fire Resistance Tests

Test Test Type Performance Achieved
BS476: Part 22

ISO 9705
IMO MSC.36(63)
IMO MSC.61(67)

Fire insulation and integrity

Room corner test
IMO Code of Safety for High Speed Craft
Smoke and Toxicity

Greater than 1 hour insulation and integrity


Fire Restricting Material
Conformance to Resolution

TOP