Certification for Mass Transit
Performance in Reaction to Fire Test |
||
Test | Performance of Borden Cellobond phenolic FRP laminate | Performance Category |
BS476:
Part 7 BS476: Part 6 BS6853 B5.2 NF F 16-101 ASTM E162 ASTM E662 DIN 5510 ASTM E84 BS6853 (EN 2825, 2826) |
class
1 i = 0.8, I=8.1 Ao(ON) = < 1.0 Ao(OFF)= < 1.5 M1/F1 Flame spread index = 2 Non-flaming 7; Flaming 23 Flammability S4; Smoke SR2; Drips ST2 Flame spread 5, Smoke Density 5 R=0.27 |
Class
1 Class 1/0 Meets London Underground requirements M1/F1 Very low flame spread Very low Smoke Best possible rating Class 1 (best possible) Category 1A |
Performance in Fire Resistance Tests |
||
Test | Test Type | Performance Achieved |
BS476:
Part 22 ISO 9705 IMO MSC.36(63) IMO MSC.61(67) NES 711 NFX 10-702 NES 713 |
Fire
insulation and Integrity Room Corner Test IMO Code Of Safety For High Speed Craft Smoke &Toxity Smoke Index Smoke Density Toxicity Index |
Greater
than 1 hour insulation and integrity Fire Restricting Material Conformance to Resolution |
Performance in these test is usually laminate and design dependent |
Certification for Aerospace/Defence
Performance in Fire Resistance Tests |
||
Test | Performance of Borden Cellobond FRP Phenolic laminate and ETP | Performance Category |
CAA
8 Issue 2 ATS 1000.001 BS2782 BS476 Part 6 BS476 Part 7 MIL-R-9299C Type A MIL-R-9299C Type B FAR/JAR 25.853(c&d) FAR/JAR 25.853(c&d) FAR/JAR 25.853(c&d) |
DS 1.5 mins, 5, 4 mins, 25 >250 ºC Class 0 Class 1 APP.F. Pt.IV(g) Heat release APP.F.Pt.V (b) smoke emission test APP.F Pt.I (a) (1) (i) flammability test |
Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass |
Certification for Building/Construction
Performance in Reaction to Fire Test |
||
Test | Performance of Borden Cellobond phenolic FRP laminate | Performance Category |
BS476:
Part 7 BS476: Part 6 BS6853 B5.2 DIN 4102 NEN1076 (is replaced by NEN 6065) |
class
1 i = 0.8, I=8.1 Ao(ON) = <1.0 , Ao(OFF) = <1.5 class B1 class 1 |
Class
1 Class 1/0 Meets London Underground requirements Class B1 Class 1 |
Performance in Fire Resistance Tests |
||
Test | Test Type | Performance Achieved |
BS476:
Part 22
ISO 9705 |
Fire
insulation and integrity
Room corner test |
Greater
than 1 hour insulation and integrity
|